3-22 DL600E E1 Data Multiplexer UserÕs Guide
Forward Over IBC (In-Band Communication)ÑEnabled or
Disabled (DefaultÑDisabled)
EnabledÑEnables the automatic forwarding of SNMP packets
over In-Band Communication from the local DL600E unit to the
remote unit.
TRAP 1st NMS IP AddressÑnnn.nnn.nnn.nnn
(DefaultÑ
0.0.0.0)
nnn = 0 through 255
Enter the IP address of the Þrst Network Management Server. The
DL600E unit sends trap messages to this server. You can specify
up to
three IP addresses of network management stations to
which the DL600E unit sends traps.
TRAP 2nd NMS IP AddressÑnnn.nnn.nnn.nnn
(DefaultÑ
0.0.0.0)
nnn = 0 through 255
Enter the IP address of the second Network Management Server.
The DL600E unit sends trap messages to this server.
TRAP 3rd NMS IP AddressÑnnn.nnn.nnn.nnn
(DefaultÑ
0.0.0.0)
nnn = 0 through 255
Enter the IP address of the third Network Management Server.
The DL600E unit sends trap messages to this server.
D Note: If all three TRAP NMS IP addresses are set,
the DL600E unit sends a trap to all three network
management servers.
Output PortÑCOMM (DefaultÑCOMM)
Select the DL600E NMS port to which traps are sent.
Community Strings
Get
(text string) (Default Ñ public)
Enter an alphanumeric text string (maximumÑ32 characters).
The DL600E
SNMP agent uses this text string to check GET
requests for the
SNMP conÞguration from the SNMP
management station.
Set (text string) (Default Ñ public)
Enter an alphanumeric text string (maxÑ32 characters). The
DL600E
SNMP agent uses this text string to check SET
requests from the
SNMP management station to set the SNMP
conÞguration.